Fire alarm control panel in a mechanical room

FireSight FACP-1 · System normal

Voice memo in.
NFPA 72 report out.

──── Main menu ────
FIRESIGHT FACP-1
SYSTEM NORMAL
* NO ACTIVE ALARMS *
> MENU_

24 hr

Standard turnaround — same day on rush jobs

$39

Per standard report, against $50–150 of write-up labor

3–5 hrs

Paperwork saved per technician, every week

How it works

Zero behavior change for your technicians

01

Send what the truck already has

The 3–10 minute voice memo, photos of the panel and every deficiency, walkthrough video, typed notes. No app for your techs to learn, no forms to fill.

02

We map the jurisdiction

The site address resolves to its enforcing AHJ: the adopted NFPA 72 edition, local amendments, and how the report gets filed — Compliance Engine, portal, or paper.

03

A signed-ready report comes back

Your logo on the header, findings matched to code citations, photos placed against deficiencies, signature blocks ready for your licensee and the building rep.

The app knows your AHJ

Fire code isn't one code. Houston routes reports through The Compliance Engine on a Texas state license baseline; New York City enforces its own fire code under FDNY certificates; two Bergen County boroughs can read the same standard differently.

Every FireSight report is stamped with the edition your jurisdiction actually enforces — and tells you where it has to be filed.

City of Houston Fire Marshal's Office

TX
NFPA 72 enforced
2019 (per TX adopted standards, 28 TAC §34.607)
Reports filed via
The Compliance Engine (Brycer)

FDNY — Bureau of Fire Prevention

NY
NFPA 72 enforced
As modified by the NYC Fire Code and FDNY rules
Reports filed via
FDNY procedures / premises records

Local fire official (Bergen County municipality)

NJ
NFPA 72 enforced
Per NJ Uniform Fire Code adoption (N.J.A.C. 5:70)
Reports filed via
Municipal fire official / local fire prevention bureau

Packs are maintained for Texas metros and the Tri-State area, with a verified national baseline everywhere else.

Garden State Fire Alarm Co.

NJ Fire Alarm License · P00212

Record of
Inspection & Testing

Property: Lincoln Elementary School, Hackensack, NJ

AHJ: Local fire official (Bergen County) · N.J.A.C. 5:70

1. Roof — RTU-2 · impairment

Duct smoke detector failed to latch on test; unit requires replacement.

NFPA 72 14.4.3.2, Table 14.4.3.2(17)(g)

2. FACP — batteries · impairment

Standby batteries dated 2021 failed load test; both replaced on site.

NFPA 72 14.4.3.2, Table 14.4.3.2(6)

Licensed technician

Building representative

Paperwork your AHJ takes seriously

  • Your business name, license and logo on the header — your client never sees ours
  • Findings mapped to NFPA 72 citations from a curated table, stamped with the adopted edition
  • Deficiency photos placed against their findings, EXIF evidence intact
  • Signature blocks for your licensee and the building representative

Pricing

One platform fee runs the whole shop

Reports, your client list, the scheduling calendar, technician dispatch, and client invoicing — all included. Priced to undercut the generic CRMs, with enough reports built in that the plan pays for itself. Every plan starts with a 14-day free trial.

Field

$99/mo

Run the whole shop — schedule, dispatch, bill.

  • Up to 5 users
  • 15 inspection reports/month included, then $19 each
  • Client list (CRM) + scheduling calendar
  • Assign & dispatch jobs to your technicians
  • Invoice your clients and collect payment
Start free trial

Pro

Most popular

$249/mo

For growing companies running multiple crews.

  • Up to 20 users
  • 50 reports/month included, then $14 each
  • Everything in Field
  • Custom report branding & templates
  • Review requests + priority support
Start free trial

Company

$499/mo

Unlimited seats for multi-branch operations.

  • Unlimited users
  • 150 reports/month included, then $11 each
  • Everything in Pro
  • Multi-location & API access
  • Dedicated onboarding & support
Start free trial

Solo — no subscription

from $39 / report

Just need the reports? Generate branded, code-referenced documentation and pay per report ($39 / $69 / $129, deficiency letters $15; rush +50%). Your first report is free — upgrade to a plan whenever you want the client list, calendar, and invoicing.

Prepared by us.
Signed by you.

FireSight is a documentation preparation service. Your licensed technician performs the inspection, reviews every line, and certifies the report — we never inspect, certify or sign. That line is printed on every report footer.

  • Inspection records describe building security infrastructure — data is encrypted, isolated per firm, and never used to serve other customers.
  • Citations come from a curated code table, never generated. Ambiguities surface as questions instead of guesses.
  • Any correction is re-issued free within 24 hours — the corrections log is our accuracy record.

Stop writing reports at the kitchen table

Send your next inspection's voice memo and photos. The finished report is the pitch.

Get your first report free